chainflex® bus cable CFBUS.LB Typical application areas
- For heaviest duty applications
- Almost unlimited resistance to oil, also to bio-oils, Class 4
- Indoor and outdoor applications without direct solar radiation
- Unsupported travel distances and up to 400 m and more for gliding applications, Class 6
- Bus connection cable for storage and retrieval equipment, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications
Guaranteed service life for this series according to the guarantee conditions
More information: chainflex® Guarantee| Double strokes* | 5 million | 7.5 million | 10 million |
|---|
| Temperature, | CFBUS .001 -.049 | CFBUS .050-.070 | CFBUS .001-.049 | CFBUS .050-.070 | CFBUS .001-.049 | CFBUS .050-.070 |
| von/bis [°C] | R min. [Faktor x d] | R min. [Faktor x d] | R min. [Faktor x d] | R min. [Faktor x d] | R min. [Faktor x d] | R min. [Faktor x d] |
| -35 / -25 | 12,5 | 10 | 13,5 | 11 | 14,5 | 12 |
| -25 / +60 | 10 | 7.5 | 11 | 8.5 | 12 | 9.5 |
| +60 / +70 | 12.5 | 10 | 13.5 | 11 | 14.5 | 12 |
* Higher number of double strokes possible - use the function of service life calculation on this page
Technical note bus cables chainflex® bus cables are specially developed and tested for continuous use in e-chains® applications. Depending on
the used outer jacket material and the design principle, the bus cables are designed for different mechanical requirements
and media resistances.
The electrical design is selected in such a way that, on the one hand, the electrical properties of the respective bus specification are reliably fulfilled
, and the greatest importance is also placed on high EMC safety. A permanent stability of the
electrical values despite permanent movement is also ensured.
However, the entire transmission property in a complete bus communication system is not exclusively
dependent on the cable used. Rather, it requires an exact coordination of all components (electronic components,
connection technology and cable) as well as the consideration of the maximum transmission rates which are dependent on the respective systems
in relation to the required data transmission rates. A cable is therefore not solely responsible for the secure transmission of the
signals.
igus® advises you in the design of the appropriate bus system, taking into account all these factors and carrying out extensive tests to
ensure the process reliability of your system from the start.
Certificates and standards